UA · Unequal Angles

150x90x10UA

150x90x10UA Unequal Angle

  • AS/NZS 3679.1:2016
  • Design: AS 4100:2020
  • Unverified
Weight Surface area Equivalents XML
Mass18.16kg/m
A2,314mm²
Ix5.39610⁶ mm⁴
Zx54.210³ mm³
150x90x10UA cross-section
Cross-section drawn to scale from nominal dimensions. Cross-hair marks the centroid.

Dimensions

ParameterSymbolValueUnitData
Leg length 1b1150.0mmU
Leg length 2b290.0mmU
Thicknesst10.0mmU
Root radiusr18.0mmU

Section Properties

ParameterSymbolValueUnitData
General
Mass per metre mass18.16kg/mC
Gross area A2,314mm²C
Centroid x̄ (from left/heel) xc20.6mmC
Centroid ȳ (from bottom) yc50.4mmC
About x-axis (major)
Second moment of area IxAbout centroidal axis parallel to leg b2 Ix5.39610⁶ mm⁴C
Elastic section modulus Zx (min) Zx54.210³ mm³C
Radius of gyration rx rx48.3mmC
About y-axis (minor)
Second moment of area IyAbout centroidal axis parallel to leg b1 Iy1.49710⁶ mm⁴C
Elastic section modulus Zy (min) Zy21.610³ mm³C
Radius of gyration ry ry25.4mmC
Principal axes
Major principal second moment I1 I15.99410⁶ mm⁴C
Minor principal second moment I2 I20.90010⁶ mm⁴C
Minimum radius of gyration r2 r219.7mmC
Principal axis angleAngle between x-axis and major principal axis alpha20.0°C
Torsion & warping
Torsion constant JApproximate thin-walled value, fillets neglected J0.07710⁶ mm⁴C
Surface area
External surface areaToe radii neglected extArea0.477m²/mC

Nominal designation mass 18.00 kg/m; calculated 18.16 kg/m (+0.9%).

Steel Grades

GradeStandard fy MPafu MPa NoteData
300 AS/NZS 3679.1:2016 320 440 Typical grade supplied – confirm availability with supplier U

Strengths shown for governing thickness t = 10.0 mm. Density 7850 kg/m³, E = 200 000 MPa.

Source & Verification

Source publisher
Pending verification – nominal dimensions entered by the application developer
Source document
AS/NZS 3679.1:2016 Structural steel – Hot-rolled bars and sections
Edition
2016
Publication year
2016
Page reference
—
Last updated
2026-10-12
Verification status
Unverified

Toe radii neglected in calculated properties. Nominal dimensions require verification against AS/NZS 3679.1 and the manufacturer catalogue before design use.

Report a data correction for this section