UA · Unequal Angles

100x75x8UA

100x75x8UA Unequal Angle

  • AS/NZS 3679.1:2016
  • Design: AS 4100:2020
  • Unverified
Weight Surface area Equivalents XML
Mass10.60kg/m
A1,350mm²
Ix1.35510⁶ mm⁴
Zx19.710³ mm³
100x75x8UA cross-section
Cross-section drawn to scale from nominal dimensions. Cross-hair marks the centroid.

Dimensions

ParameterSymbolValueUnitData
Leg length 1b1100.0mmU
Leg length 2b275.0mmU
Thicknesst8.0mmU
Root radiusr18.0mmU

Section Properties

ParameterSymbolValueUnitData
General
Mass per metre mass10.60kg/mC
Gross area A1,350mm²C
Centroid x̄ (from left/heel) xc19.0mmC
Centroid ȳ (from bottom) yc31.3mmC
About x-axis (major)
Second moment of area IxAbout centroidal axis parallel to leg b2 Ix1.35510⁶ mm⁴C
Elastic section modulus Zx (min) Zx19.710³ mm³C
Radius of gyration rx rx31.7mmC
About y-axis (minor)
Second moment of area IyAbout centroidal axis parallel to leg b1 Iy0.65710⁶ mm⁴C
Elastic section modulus Zy (min) Zy11.710³ mm³C
Radius of gyration ry ry22.1mmC
Principal axes
Major principal second moment I1 I11.65810⁶ mm⁴C
Minor principal second moment I2 I20.35410⁶ mm⁴C
Minimum radius of gyration r2 r216.2mmC
Principal axis angleAngle between x-axis and major principal axis alpha28.8°C
Torsion & warping
Torsion constant JApproximate thin-walled value, fillets neglected J0.02910⁶ mm⁴C
Surface area
External surface areaToe radii neglected extArea0.347m²/mC

Nominal designation mass 10.80 kg/m; calculated 10.60 kg/m (-1.9%).

Steel Grades

GradeStandard fy MPafu MPa NoteData
300 AS/NZS 3679.1:2016 320 440 Typical grade supplied – confirm availability with supplier U

Strengths shown for governing thickness t = 8.0 mm. Density 7850 kg/m³, E = 200 000 MPa.

Source & Verification

Source publisher
Pending verification – nominal dimensions entered by the application developer
Source document
AS/NZS 3679.1:2016 Structural steel – Hot-rolled bars and sections
Edition
2016
Publication year
2016
Page reference
—
Last updated
2026-10-12
Verification status
Unverified

Toe radii neglected in calculated properties. Nominal dimensions require verification against AS/NZS 3679.1 and the manufacturer catalogue before design use.

Report a data correction for this section